Atomic Absorption Spectrophotometer

Item No.: AA 7800
The Atomic Absorption Spectrophotometer is fully PC controlled. It can be flexibly equipped with optional graphite furnace, auto sampler and hydride generator. Unique optical mechanical design, safe and convenient flame system, optional background correct
INQUIRY
Description
Atomic Absorption Spectrophotometer  
 
The Atomic Absorption Spectrophotometer is fully PC controlled. It can be flexibly equipped with optional graphite furnace, auto sampler and hydride generator. Unique optical mechanical design, safe and convenient flame system, optional background correction technologies, as well as convenient functions provided by the workstation, suit your pursuit of automatic and precise test results. 
           
Features:          
1. Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.
2. Comprehensive and safe intelligent gas control module.
3. Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.
4. Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.
5. Original lamp position eight lamp holder 360 degree rotation design.
6. Novel atomizer and intelligent elevator.
7. Simple, professional, automatic and fully operated RG WIN AAS workstation software under MS window system.


Specification:
 
Models AA 7804 AA 7808 AA 7818 AA 7828
Optical System Single Beam Single Beam Single Beam Double Beam
Monochromator Czerny-Turner type, focal lengths at 350mm
Grating Holographic diffraction with 1800 lines/mm
Wavelength Range 190-900 nm
Slits Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm
Wavelength Repeatability ±0.1nm ±0.1 nm ±0.05 nm ±0.05 nm
Wavelength Accuracy ±0.3 nm ±0.2 nm ±0.15 nm ±0.15 nm
Lamp Automated 4-lamp turret Automated 8-lamp turret Automated 8-lamp turret Automated 8-lamp turret
Reading Mode T, A, C
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) ≤0.004A/30 min ≤0.003A/30 min ≤0.002A/30 min ≤0.002A/30 min
Dynamic Baseline Drift (Cu) ≤0.006A/15 min ≤0.005A/15 min ≤0.004A/15 min ≤0.004A/15 min
Background Correction Deuterium (D2) Background Correction Deuterium (D2) Background Correction and Self-absorption Background Correction
Flame Characteristic Concentration ≤0.04ug/ml ≤0.035ug/ml ≤0.02ug/ml ≤0.02ug/ml
Detection Limit (Cu) ≤0.008ug/ml ≤0.006ug/ml ≤0.004ug/ml ≤0.004ug/ml
Repeatability (Cu) RSD≤1% RSD≤0.6% RSD≤0.5% RSD≤0.5%
Acetylene Flow Control Auto 12-Level
Air Assist Control Auto 4-Level
Ignition Method PC control
Detector Wide range UV sensitive photomultiplier tube
Burner Head Titanium 100mm burner for air/acetylene operation
Nebulizer High efficiency glass nebulizer
Spray Chamber Corrosion resistant material spray chamber
Safety Protection Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched
Graphite Furnace Characteristic Amount Cd≤0.9pg, Cu≤20pg Cd≤0.6pg, Cu≤20pg Cd≤0.5pg, Cu≤20pg Cd≤0.5pg, Cu≤20pg
Detection Limit (Cu) Cd≤1.5pg, Cu≤25pg Cd≤1.0pg, Cu≤25pg Cd≤0.8pg, Cu≤25pg Cd≤0.8pg, Cu≤25pg
Repeatability (Cu) RSD≤4% RSD≤3% RSD≤2.5% RSD≤2.5%
Heating range of graphite furnace Room temperature-3000℃
High power heating range 1500-3000℃
Slope and holding time 1-255s
Heating rate Maximum heating rate 2000℃/s
Atomization heating mode Light-controlled heating, Time-controlled heating, General heating
Protective gas flow outside pipe 1 L/min
Protective gas flow inside pipe 4-speed adjustable (0, 50, 200, 250/min flow)
Safety Protection Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm
Auto Sampler Optional
Data Processing Measuring method Flame method, Graphite furnace method, Hydride generation-Atomic absorption method, Flame emission method
Concentration calculation method Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method
Repeat measurement times 1-30 times, Calculate and give the average value of absorbance/concentration, standard deviation and relative standard deviation
Report printing Parameter printing, Data result printing
Dimensions/ Weight 850 x 650 x 550 mm/95kg
Ambient Temp. 10 ~ 35 °C
Ambient Humidity ≦85 %
Power 110/220V, 50/60Hz